SMC Networks SMC8624/48T Instrukcja Użytkownika Strona 317

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 556
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 316
S
YSTEM
M
ANAGEMENT
C
OMMANDS
4-73
Default Setting
Disabled
Command Mode
Global Configuration
Command Usage
The time acquired from time servers is used to record accurate dates
and times for log events. Without SNTP, the switch only records the
time starting from the factory default set at the last bootup
(e.g., 00:00:00, Jan. 1, 2001).
This command enables client time requests to time servers specified
via the sntp servers command. It issues time synchronization requests
based on the interval set via the sntp poll command.
The SNTP time query method is set to client mode when the first sntp
client command is issued. However, if the sntp broadcast client
command is issued, then the no sntp broadcast client command
must be used to return the switch to SNTP client mode.
Example
Related Commands
sntp server (4-71)
sntp poll (4-72)
sntp broadcast client (4-74)
show sntp (4-74)
Console(config)#sntp server 10.1.0.19
Console(config)#sntp poll 60
Console(config)#sntp client
Console(config)#end
Console#show sntp
Current time: Dec 23 02:52:44 2002
Poll interval: 60
Current mode: unicast
Console#
Przeglądanie stron 316
1 2 ... 312 313 314 315 316 317 318 319 320 321 322 ... 555 556

Komentarze do niniejszej Instrukcji

Brak uwag