Redundant Power Unit
Fault-tolerant networking!
Supports up to four switch units
AC line draws power from different supply circuit
DC line provides backup power to attached devices
Thermal overload protection
Over-voltage protection for each output channel
Over-current protection can shut down the RPU
Short-circuit protection against output channels
User Guide
SMCRPU14
Przeglądanie stron 0
1 2 3 4 5 6 ... 37 38

Podsumowanie treści

Strona 1 - Redundant Power Unit

Redundant Power UnitFault-tolerant networking!• Supports up to four switch units • AC line draws power from different supply circuit• DC line provi

Strona 2

COMPLIANCESviFrance and Peru onlyThis unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be powered by 230 V (2

Strona 3 - User Guide

COMPLIANCESvii• Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes internationales de sécurité

Strona 4

COMPLIANCESviiiBitte unbedingt vor dem Einbauen des RPU die folgenden Sicherheitsanweisungen durchlesen:WARNUNG: Die Installation und der Ausbau des G

Strona 5 - LIMITED WARRANTY

COMPLIANCESixWarnings and Cautionary MessagesWarnings (in German)Warning: This product does not contain any serviceable user parts.Warning: Installati

Strona 6

xEnvironmental StatementThe manufacturer of this product endeavours to sustain an environmentally-friendly policy throughout the entire production pro

Strona 7

ixTABLE OF CONTENTS1 About the Redundant Power Unit . . . . . . . . . . . . . . . .1-1Overview . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 8

TABLE OF CONTENTSx

Strona 9

1-1CHAPTER 1: ABOUT THE REDUNDANT POWER UNITOverviewThis Redundant Power Unit (SMCRPU14) can supply 600 Watts of backup power to four switches in the

Strona 10 - OMPLIANCES

1-2• Short-circuit protection prevents the RPU from being damaged from a short circuit on any output channel.• The RPU will operate under a no-load co

Strona 11

1-3Table 1-1 Port Status LEDsLED (1-4) Condition StatusLink Off The port does not have a valid connection to a switch.On Yellow The port has a valid

Strona 14 - Audience

2-1CHAPTER 2: INSTALLING THE REDUNDANT POWER UNITInstallationThe RPU may be placed on a desktop or mounted in a rack. Caution: DO NOT place the RPU on

Strona 15

2-2- Make sure that a separate grounded power outlet that provides 100 to 240 VAC, 50-60 Hz, is within 2 m (6.56 feet) of each device and is powered f

Strona 16

2-3MountingRPU units can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow.

Strona 17 - POWER UNIT

2-4To rack-mount devices:1. Attach the brackets to the device using the screws provided in the Bracket Mounting Kit.Figure 2-1 Attaching the Brackets

Strona 18 - 100-240V, 50-60Hz 10A

2-5Montage (Rack Mounting - German)SMCRPU14 RPU-Einheiten können an ein standardmäßiges 19-Zoll Einrichtungsrack, einen Arbeitstisch oder ein Regal mo

Strona 19 - LED Condition Status

2-6Desktop or Shelf Mounting1. Attach the four adhesive feet to the bottom of the first RPU unit.Figure 2-3 Attaching the Adhesive Feet2. Set the dev

Strona 20

2-7Figure 2-4 Power Receptacle2. Connect one end of a DC cord to the redundant power receptacle on the supported switch and the other end to an avail

Strona 21 - REDUNDANT POWER UNIT

2-8Figure 2-5 Connecting the RPU in a StackNote:For International use, you may need to change the AC line cord. You must use a line cord set that has

Strona 22 - Equipment Checklist

A-1APPENDIX ATROUBLESHOOTINGDiagnosing RPU Indicators Table A-1 Troubleshooting ChartSymptom ActionPower LED is Off• Internal power supply is disconn

Strona 23 - Mounting

38 TeslaIrvine, CA 92618Phone: (949) 679-8000Redundant Power UnitUser GuidePowers up to four SMC networking devicesJanurary 2005Pub. # 150200050500A R

Strona 24

A-2Power and Cooling ProblemsIf the PWR LED does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power co

Strona 25 - Rack-Montage

B-1APPENDIX B.SPECIFICATIONSPhysical CharacteristicsPorts4 RPU DC power outlets (IEC socket 216C743-07)LEDs Port: Link, ActivitySystem: Power, Fan, Th

Strona 26 - 100-240V

B-2Power SupplyInternal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 HzOutput 11.5 VDCPower Consumption644 W (Maximum)161 W (Maximum per port)M

Strona 27

B-3SafetyCSA/ C US (CSA 60950-00 & UL60950)CB: IEC 60950EN 60950 (TÜV/GS)

Strona 29 - TROUBLESHOOTING

INDEX-1Aadhesive feet, attaching 2-6air flow requirements 2-1Bbrackets, attaching 2-4CCE Mark 0-ivcompliances 0-iiiEMC B-2safety B-3contents of packag

Strona 30 - Flashing Yellow

INDEXINDEX-2specificationscompliances B-2environmental B-1physical B-1power B-2standardscompliance B-2IEEE B-2standards compliance 0-iiisurge suppress

Strona 32 - Compliances

38 TeslaIrvine, CA 92618Phone: (949) 679-8000FOR TECHNICAL SUPPORT, CALL:From U.S.A. and Canada (24 hours a day, 7 days a week)(800) SMC-4-YOU; (949)

Strona 33 - EN 60950 (TÜV/GS)

Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, n

Strona 34

iLIMITED WARRANTYLimited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, un

Strona 35

LIMITED WARRANTYiiWARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT O

Strona 36

COMPLIANCESiiiCOMPLIANCESFCC - Class BThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Par

Strona 37

COMPLIANCESivEC Conformance Declaration - Class BSMC contact for these products in Europe is:SMC Networks Europe,Edificio Conata II, Calle Fructuós Ge

Strona 38

COMPLIANCESvAustralia AS/NZS 3548 (1995) - Class BSMC contact for products in Australia is:SMC Communications Pty. Ltd.Suite 18, 12 Tryon Road, Lindfi

Komentarze do niniejszej Instrukcji

Brak uwag