SMC Networks TigerAccess SMC7816M Instrukcja Użytkownika Strona 725

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 962
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 724
L
INE
P
ROFILE
C
OMMANDS
29-43
Example
The following disables all tone beneath 640 kHz on the upstream band
plan.
Related Commands
lre tone (29-21)
max-power
This command sets the maximum aggregate downstream or upstream
power. Use the no form to restore the default setting.
Syntax
max-power {down | up} value
no max-power {down | up}
down – Downstream bands.
up – Upstream bands.
value – Maximum aggregate power. (Range: 0-255, in units of
0.25 dBm)
Default Setting
255 (63.75 dBm)
Command Mode
VDSL Line Profile
Example
The following sets the maximum downstream power to 14.5 dBm.
Related Commands
lre max-power (29-22)
Console(config-line-profile)#tone tx 2
Console(config-line-profile)#
Console(config-line-profile)#max-power down 58
Console(config-line-profile)#