SMCWHS-POS
1. UnpackingA. Standard Package1) EliteConnectTMMini-POS Ticket Printer 1 piece2) Control Keypad 1 piece3) User's Guide 1 piece4) Y Cable 1 piece
C. Loading Paper Roll3. Self Test of the Printer• Power up the printer while pressing and holding down the Online button. Power Indicator comes on an
4. Using the PrinterA. Connecting the Mini-POS Ticket Printer to the Wireless Hotspot Gateway • Locate an optimum location for the printer. In most in
• Connect the AC power adapter to the printer's power socket and the otherend to the electrical outlet.NOTE: Use of a different adapter may resul
5. SpecificationsA. Physical CharacteristicsPrint Method Direct thermalPaper Width 57.5 mm ± 0.5 mmEffective Print Width 48 mmPrint Speed Approx. 52 m
6. PinoutsA. Serial Connection B. Parallel ConnectionPin# Signal Pin# Signal 1/STB 15 N/C2 DATA1 16 N/C3 DATA2 17
C. Power Input PRP-058 requires DC 7.5V/2.0A power.D. Cash Drawer PortPin# Signal Description1. N/C 2. Drive Signal Cash drawer dri
7. Command SetNo. Command Hex Code Function Description1 LF 0A Prints out buffer and advances one line2 ESC J n 1B 4A n Prints out buffer and advance
FOR TECHNICAL SUPPORT, CALL:From U.S.A. and Canada (24 hours a day, 7 days a week)(800) SMC-4-YOU; Phn: (949) 679-8000; Fax: (949) 679-1481From Europe
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurateand reliable. However, no responsibility is assumed by SMC for its use, no
LIMITED WARRANTYLimited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its productsto be free from defects in workmanship and materials, unde
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEUOF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED,EITHER IN FACT OR BY OPERATIO
Federal Communication Commission Interference StatementThis equipment has been tested and found to comply with the limits for aClass B digital device,
CompliancesFCC - Class AThis equipment has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15 of the FCC
+A1: 2001 (80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)• Electrical fast transient/burst according to EN 61000-4-4:1995 + A1: 2001 (AC/DC power
11. Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer Überspannung eine Besch
EliteConnectTMMini-POS Ticket PrinterTable of Contents1. Unpacking 9A. Standard Package 92. Indicators and Connections 9A. Front Panel of the Printer